Rolling Stock Cables
EN 50264 EN 50306 EN 50382 Databus Cables NF F 63-826 NF F 63-808 NF F 63-827 RSE/STD/024 PART 6

Rolling Stock Cable

NF F 63-827 High Temperature Cable

FIREROL FRF-HT-3S-EF

3000V -Extra-Flexible High Temperature Single Core Screened & Sheathed Cables

 

 

Application

3000V -Extra-Flexible High Temperature Single Core Screened & Sheathed Cables are used as power and

control cable for protected installations inside and outside of rail and transport vehicles, where handling and

installation cost are an important factor, suitable for used in control, auxiliary and main circuit wiring such as

cable harnesses, switchboards and control panels, driver desks etc.

Construction

Conductor: Stranded tinned copper wires to IEC 60228 Class 6

Insulation: Halogen free silicone rubber

Reinforcement: Textile braid

Sheath: Halogen free silicone rubber

 

3000 V NF F 63-827 (FRF-HT-3S-EF)

                                                          A. Conductor B. Insulation C. Reinforcement D. Sheath

Electrical & Mechanical Properties

Nominal Voltage:3000V

Maximum Conductor Temperature:120°C/140°C

Minimum Permissible Ambient Temperature:-40°C~+135°C

Bending Radius:3 × Overall Diameter

Standards

NF F 63-827

NF F 16-101

Fire Performance in general

EN 50265-2-1; IEC 60332-1-2; NF C 32-070 2.1 (C2) Vertical flame propogation for a single insulated wire or cable
EN 50266-2-4 + EN 50305; IEC 60332-3-24;
NF C 32-070 2.2 (C1); VDE 0472 Teil 804
Vertical flame spread of vertically mounted bunched wires or cables
EN 50268-2; IEC 61034-2; NF C 32-073 ;
NF C 20-902; NF F 16 101; VDE 0472 Teil 816
Low Smoke Emission
EN 50267-2-1; IEC 60754-1; NF C 32-074;NF C 20-454; VDE 0472 Teil 815 Halogen Free
EN 50267-2-2/3; IEC 60754-2; NF C 32-074;NF C 20-453; VDE 0472 Teil 813 Low Corrosivity (Acidity & Conductivity)
EN 50305; NFX 70-100; NFF 63808; TM1-04; BS6853 Low Toxicity
NFF 16101; NFF 63808; BS6853 Smoke index
EN45545-2 Requirement for fire behavior of materials & components
R15/R16

FRF-HT-3S-EF 3000V

Nominal Cross Sectional Area Number & Nominal Diameter of Strands Nominal Insulation Thickness Overall Diameter Weight
Min. Max.
mm² No/mm mm mm mm kg/km
25.0 800/0.20 2.8 12.0 13.2 390
35.0 1120/0.20 2.8 13.2 14.7 500
50.0 705/0.30 3.0 15.2 16.7 680
70.0 990/0.30 3.2 17.1 18.8 930
95.0 1340/0.30 3.2 19.0 21.0 1150
120.0 1690/0.30 3.3 21.0 23.1 1470
150.0 2123/0.30 3.3 22.8 25.0 1800
185.0 1470/0.40 3.4 24.7 27.1 2240
240.0 1905/0.40 3.6 27.6 31.2 2820

Note: The parameters listed above are nominal values as per cable standards. Actual values may vary due to material and manufacturing process variations. For precise specifications or customized requirements, please contact us for further information